Control keys
Table of keys:
Key Modifier Action
F1 Toggles help screen off/on
Shift Toggles text mode help screen on/off
Alt Toggles debug screen on/off
F2 Cycle reward style to next available reward style
Rwrd Reward (signal above threshold)
Down Reward (signal below threshold)
Cntr Reward (signal close to threshold)
Elev Reward (signal above threshold, clamp to threshold)
DevU Reward (deviation above)
DevD Reward (deviation down)
Shift Cycle reward style to previous available reward style
Ctrl Toggle state-hold-required logic which inhibits rewards unless a state is maintained for the specified rate/time.
F3 Cycle feedback mode to next available mode
Shift Start/terminate popup menu to select an available feedback mode
Ctrl Toggle game 'color' between Green, Blue
Alt Toggle lowpass filter on/off
F4 Cycle to next stage; turns off autostage logic
Shift Turn autostaging back ON
Ctrl Set frequency values to ending values from last run.
F5 Begin/pause feedback
Ctrl Begin/pause feedback; turn autostaging OFF
F6 Save 16 second data sample for later printout
Ctrl *Change feedback data source: raw,playback,signal generator
Alt Signal generator setup
F7 Show integral value instead of signal value on display (3 settings: just waveshape, just integral, both)
Shift Toggle fixed colors on/off
Ctrl Toggle impedance mode (if hardware-supported and in Pause)
Alt Toggle calibration mode (if hardware supported)
F8 Start/terminate editor
Shift Insert marker. User has (60 second) option of entering a line of text.
Ctrl *toggle saving debug data
Alt Toggle artifact inhibit control on/off
F9 Scale adjust. If no streams are selected (highlighted), performs autoscale of all non-lowpass streams.
If a stream is selected, toggles between threshold and scale adjustment (using +/-).
Ctrl *toggle game activity control flag (debug only)
Alt Toggle DC compensation on/off
F10 Decrease scale used to display FFT data and long term data
Shift Increase scale used to display FFT data and long term data
Ctrl Toggle FFT display on/off
Alt Toggle FFT highlight mode
F11 Autothreshold. If a stream is selected, choose appropriate threshold value for only that stream.
If the stream is a lowpass stream, choose threshold based on 1% over threshold as target.
If no streams are selected, choose appropriate threshold value for all non-lowpass streams.
If the user-specified threshold percentage is zero, no autothreshold action is ever taken on
that stream.
Alt Reset history values (used for display. autogoal)
Ctrl Toggle automatic autothreshold at beginning of each reset period (or specified time frame) on/off.
F12 Cycle display shown. Current displays are : brainwave, long-term, Spectral Mirror,zscore,realtime summary
Shift Cycle display shown in reverse order
Ctrl Toggle drawing speed of brainwave screen between fast and slow (normal).
Alt Toggle "hide unused traces" mode.
Turns off DISPLAY of unused input/FFT traces to minimize screen confusion.
Page Up (any) Cycle trace selection upwards
Up arrow Cycle trace selection upwards
Ctrl Increase reward center frequency or inhibit upper edge of selected stream.
If no trace is selected, adjust ALL reward streams at the same time.
Page Down (any) Cycle trace selection downwards
Down arrow Cycle trace selection downwards
Ctrl Decrease reward center frequency or inhibit upper edge of selected stream.
If no trace is selected, adjust ALL reward streams at the same time.
Right arrow Ctrl Increase frequency of reward lower edge (decreasing width) or inhibit lower edge of selected trace.
Left arrow Ctrl Decrease frequency of reward lower edge (increasing width) or inhibit lower edge of selected trace.
Spacebar (any) Toggle between Therapist display and game display if NOT entering text for an F8 mark
Scroll Lock (any) Toggle between Therapist display and game display
Pause (any) PLAYBACK ONLY. Pause/resume playback
Esc (any) Exit popup screen if shown (goal/threshold, tactile, volume, help, debug).
Otherwise, exit realtime processing and return to top menu
+ or = Increase threshold/scale value on selected stream.
Shift Increase threshold/scale value on selected stream by 1/2 step
- Decrease threshold/scale value on selected stream.
Shift Decrease threshold/scale value on selected stream by 1/2 step
Enter (any) End scale/threshold/popup selection. If a scale value is currently highlighted,
Enter just switches to threshold modification mode.
If a threshold is highlighted, deselects trace.
A Alt Start/terminate option to change the text for the site that the A channel is connected to.
Automatically terminates (without change) after 60 seconds.
B Alt Start/terminate option to change the text for the site that the B channel is connected to.
Automatically terminates (without change) after 60 seconds.
P Popup/remove peripheral controls menu
Alt *Capture a screen dump of the current screen
Delete (any) Delete highest priority message from display
% or G Popup/remove target threshold setting menu
V Popup/remove volume setting menu
T Popup/remove tactile feedback control menu
S Popup/remove game control menu (only for supported games)
D Popup/remove therapist display control menu
E Popup/remove expert control menu
Alt Change eyes open/closed status
F Popup/remove game feedback display control menu
Items marked with an asterisk (*) are provided as debug aids only.