Contents - Index


What's New in 4.2.2 

 

Things new in 4.2.2 not already in 4.2.1s 

     (although some have been in private 4.2.1 beta releases "t" and "u"):

 

   * Corrected Standard Deviation computation in realtime summary display

   * Corrected tailoring bug that ignored tailored value of frequency step

   * Added option to change frequency step size during realtime

   * Added new sound control modes (managed by overall reward %)

   * Jumpbox/Boxlights now have option to display images in reward box.

   * Biological sex of client now recorded for later data correlation/analysis.

   * Added menu and controls for double-blind study controls.

   * Added message about incorrect raw artifact threshold settings.

   * Removed floppy disk options

   * Added display of raw values in review of screening data

   * Corrected (crash) bug in Bolights/Jumpbox

   * Corrected (crash) bug in Variable-Dots Mazes

   * Corrected Review graph logic so (red) lines show on long graphs

   * Corrected recomputation of 2nd inhibit averages in Review

   * Pdelta feedback mode changed so that larger values reflect better coherence.

   * Preliminary support for the TTUSB interface.

   * Additional utilities added to base release.

   * Added Unity feedback mode.

 

 

   * Autothreshold settings are now set by session plan stage

   * A clincian can now enable a remote client to edit the remote session plan

   * Several destination locations are now chooseable for Consultation Exports

   * Option for peripheral outputs in metric units

   * Option to preset FFT displays off at start of session

   * Option to select fast brainwave display at start of session

 

   * Hyphens now allowed in client ID

   * Option added to automatically generate Consultation Export of sessions

   * Option added to allow user selection of voltage/power for ratios

   * Several new feedback modes (some experimental)

   * A method to allow telephone updates to dongle sessions and remote sessions

 

   *A message saying NOT RECORDING when users exceed 90 minutes.

   *A minor fix in EDF+ export files.

   *"updated" esiPro driver files.

   *Debug display now shows input device along with any decoded subtype

   *IOtest now shows esiPro decoded subtype

 

    * Fixed erroneous review screen tabular selections that didn't match graphical selections

    * Remove extraneous client index rebuild on new clients

 

    * Add defensive correction for incorrectly-formatted MonitorAB summary files (single site!)

    * Correct debug-only labels for 2nd device

 

    * Updated help file to match documentation

    * New version since there were SOOOO many  versions

 

    * Message about game termination added

    * Stored dongle# and s/w version into raw file headers

    * provisions for inhibiting volume control popup for unsupported games

    * provisions for future EEG Software games

    * debug method to inhibit loading of sub-Hz filters

 

    * Flush received message queue after end-of-maze/picture received

    * Resize birds/stars for 800x600 displays

    * Decode print command messages for single-computer modes

    * Kludge repair on incorrect Windows-DX9-created .BMP file headers

 

    * Catchup on graphics library updates (but no functional changes)

    * Fix game select/tailoring menu for two columns if many games installed

 

    * Yet another set of J&J DLLs

    * New communications DLLs which require only Therapist id of client

    * Another fix for people who run longer than 90 minutes (bad period limits in summary file)

 

    * Fix scale message to have scales matching the strand order

    * Support decimation for sub-Hz filters

    * Allow remote clients to status the remote flash drive

 

    * Duplicate scale setting for both reward data channels

    * Force sending of scales whenever there is a subchannel (green/blue) change

 

    * Added method for feedback rewards within a range (band) of settings.

    * Added in-session controls for various (expert) adjustments (minimum reward time, artifact lockout counts/times, on-task times/percentages).

    * Added one-second running averages to export summary data.

    * Corrected bug in using minus sign when entering sites during realtime.

    * Put latest version of iotest in release.

    * Added some debug methods for vendor game testing.

 

 

Note:  the release will have a set of 1/100 Hz filters decimated to 64 samples/second (for the range below 1 Hz) but they must be manually enabled!!!